Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 633-636, 2018.
Article in Chinese | WPRIM | ID: wpr-807060

ABSTRACT

Objective@#To assess psychological acceptance and occupational stress of medical staff, analyze the relationship among personality, psychological acceptance and occupational stress and discuss the direct or indirect effects of personality to occupational stress.@*Methods@#The gaseous four kinds of carboxylic acids in the workplace air were simultaneously collected by silica gel tube, and then desorbed by deionized water and eluted by ion chromatograph. The the content was detected by conductivity detector.@*Results@#The linear relationship was good in the concentration range of about 0~140 mg/L. The correlation coefficient r>0.999, and the maximum detection limit was 4.5 μg/mL. The sampling efficiency of the four carboxylic acids ranges from 96.10%~100.27%. Through the sample added recovery experiments, the low and high content of the silicone tube samples were detected; and the range of desorption efficiency was 82.18%~100.12%; the range of precision was 0.70%~3.71%.@*Conclusion@#This method adopts deionized water to desorb samples, and the application of ion chromatography detection have reached the requirements of《Guidelines for the establishment of occupational health standards, Part 4: Determination of chemical substances in workplace air》, which can be used in four kinds of workplace air detection of carboxylic acid compounds.

2.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 474-476, 2015.
Article in Chinese | WPRIM | ID: wpr-350567

ABSTRACT

<p><b>OBJECTIVE</b>To establish a rapid determination method with gas chromatography-mass spectrometer (GC-MS) for thiodiglycolic acid (TDGA), a vinyl chloride (VCM) biomarker.</p><p><b>METHODS</b>A high- sensitivity determination method was established using a moderate methyl esterification instead of methyl esterification of highly toxic diazo reaction.</p><p><b>RESULTS</b>The standard curve regression linear equation of the method was: y=8460.5x-4758.2, the linear coefficient was 0.999 7, the minimum quantity concentration was 2.0 µg/L, the range of precision value was 0.81%-2.38%, and the average recovery of standard addition was 99.0%-102.9%.</p><p><b>CONCLUSION</b>This method reduces the risk of traditional methyl esterification, improves the determination sensitivity compared with the GC-FPD method, and meets the determination requirement of TDGA.</p>


Subject(s)
Humans , Gas Chromatography-Mass Spectrometry , Thioglycolates , Urine , Vinyl Chloride
SELECTION OF CITATIONS
SEARCH DETAIL